Retractable Injection Quill EMT

EMT Retractable Injection Quill is a specialized device engineered by Shenyang EMT Piping Technology Co., Ltd., designed to facilitate the accurate and controlled injection of chemical inhibitors directly into pipelines. This is essential for minimizing corrosion, a common challenge in the oil, gas, and chemical industries. The retractable design of the quill ensures it can be inserted or removed from the pipeline without needing to shut down the system, thereby enhancing operational efficiency and safety.

EMT Retractable Injection Quill is a specialized device engineered by Shenyang EMT Piping Technology Co., Ltd., designed to facilitate the accurate and controlled injection of chemical inhibitors directly into pipelines. This is essential for minimizing corrosion, a common challenge in the oil, gas, and chemical industries. The retractable design of the quill ensures it can be inserted or removed from the pipeline without needing to shut down the system, thereby enhancing operational efficiency and safety.

Chemical Injection Quill

1. Order Information

Access Fitting Body

Model  
EMT-CIPA Access Fitting Body of Coupon, Injector, Probe assembly
  – The material of Access Fitting Body
0 CS
1 316SS
2 316LSS
3 DUPLEX SS
  The Type of Access Fitting Body
B 2″Welded(suffix “pressure rating” can be added to B)
F 2″ANSI Flange(suffix “pressure rating & sealing type” can be added to F
  -Tee Size- pressure rating & sealing type if flanged end
0 No Tee
1 1/4″NPT(F)Tee
2 1/2″NPT(F)Tee
3 3/4″NPT(F)Tee
4 1″NPT(F)Tee
5 Hole for 1/4″SWN Flange
6 Hole for 1/2″SWN Flange
7 Hole for 3/4″SWN Flange
8 Hole for 1″SWN Flange
  -Protective Cover Type/ Material
0 No Protective Cover Material
1 Without hole CS or 0
2 With hole SS or 1
3 Bleed Valve DSS or 3
4 Bleed Valve, & Pressure Gauge  
For Example:EMT-CIPA-0F600#RF-2-1/CS shows  2″ANSI 600#RF Flange Access Fitting Body in CS, 1/2″NPT(F)Tee, Protective Cover in CS without hole

0F600#RF: 0F_ Access Fitting Body is Flanged in CS , 600#RF _Size is 2″ANSI 600#RF ,

2:Tee size is 1/2NPT(F)

1: Protective cover type is without hole

/CS: Protective cove material in CS

Sampler & Injector

Model
SI Sampler & Injector
  -Code Plug
Pxxx Type Material Sealing Material
0 No Request 0 CS 0 No Request
1 Hollow Plug Body 1 316SS 3 DSS 1 Viton O-Ring / PTFE Primary Packing
2 Solid Plug Body 2 316LSS 4 INCONEL 2 HNBR
  – Code Injection Nut
Nxx Connection Size Material
0 No Request 0 CS
1 1/4″ 1 316SS 3 DSS
2 1/2″ 2 316LSS 4 INCONEL
  – Code Sampling & Injection Tube
Sxxx-Lx″ Connection Size Material Nozzle Line size(x″)
0 No Request 0 CS 0 No Request The most effective position for injection is generally at the center of the pipe
1 1/4″ 1 316SS 1 Open
2 1/2″ 2 316LSS 2 Quill
    3 DSS 3 Cap & Core
    4 INCONEL    
  – Code Type and Size of components connected to Tee and material of components
Txx Connection Size Material
0 No Request 0 CS
1 1/4″Nipple a 1/4″Nipple and Valve 1 316SS
2 1/2″Nipple b 1/2″Nipple and Valve 2 316LSS
3 3/4″Nipple c 3/4″Nipple and Valve 3 D SS
4 1″Nipple d 1″Nipple and Valve 4 INCONEL
5 1/4″SWN Flange* e 1/4″Nipple and Flange    
6 1/2″SWN Flange f 1/2″Nipple and Flange    
7 3/4″SWN Flange g 3/4″Nipple and Flange    
8 1″SWN Flange h 1″Nipple and Flange    
For Example:SI-P221-N12-S122-L4″-T22   SI:Sampling & Injection Assembly,P221: Solid Plug Body in 316LSS Viton O-Ring and PTFE Primary Packing,N12:Injection Nut Connection Size is 1/4″and Material is 316LSS,S122:Injection Tube Connection Size is 1/4″ and Material is 316LSS.Type of nozzle is quill,L4″:For 4″pipe. T22: Connection Size of Nipple connected to Tee is 1/2″NPT(M), Nipple material is 316LSS

Note: SWN Flange is special WN Flange      

Example for a set of Sampler & Injector Assembly:

EMT-CIPA-0F600#RF-2-1+ SI-P221-N12-S122-L4-T22

2. Design and Construction of Retractable Injection Quill

Chemical Sampling Quill

Constructed for durability and precision, the quill includes various nozzle options, allowing customization based on the specific chemical injection requirements of different systems. The robust internal assembly features a solid plug body, an injection nut, and an injection tube, all crafted to ensure reliable and effective performance under varying operational conditions.

3. Integration and Compatibility 

Connection to the pipeline system is streamlined and secure, with components such as an NPT nipple, a manual valve, and an SWN flange facilitating easy integration into existing infrastructure. The versatile process connection options, including 2″ flanges, 2″ Flareweld access fittings, and 1″ Nipple to NPT ball valves, allow the quill to be adapted to a wide range of pipeline sizes and configurations.

4. Operational Parameters

chemical injection quill

Operating within a temperature range from -20 ℃ to 150 ℃, the EMT Retractable Injection Quill is capable of handling extreme environmental conditions, making it suitable for a variety of geographic and climatic scenarios. Furthermore, with a pressure rating of up to 6000 PSI, dependent on the flange size used, it can withstand high-pressure environments typical in industrial and energy production settings.

5. Benefits and Impact of Retractable Injection Quill

The EMT Retractable Injection Quill not only delivers chemical inhibitors efficiently but also ensures that the injection process does not interrupt pipeline operation. This feature is particularly valuable in continuous flow systems where downtime can lead to significant operational losses. Overall, the quill is a critical component for maintaining pipeline integrity and extending the lifespan of industrial piping systems, reflecting EMT’s commitment to innovation and customer satisfaction in providing advanced technological solutions.

There are no reviews yet.

Be the first to review “Retractable Injection Quill EMT”